Home ProductsBenchtop Fume Hood

0.3-0.8m/s Inflow Air Velocity Small Fume Hood , CE Certificated Chemical Exhaust Hood

0.3-0.8m/s Inflow Air Velocity Small Fume Hood , CE Certificated Chemical Exhaust Hood

    • 0.3-0.8m/s Inflow Air Velocity Small Fume Hood , CE Certificated Chemical Exhaust Hood
    • 0.3-0.8m/s Inflow Air Velocity Small Fume Hood , CE Certificated Chemical Exhaust Hood
    • 0.3-0.8m/s Inflow Air Velocity Small Fume Hood , CE Certificated Chemical Exhaust Hood
    • 0.3-0.8m/s Inflow Air Velocity Small Fume Hood , CE Certificated Chemical Exhaust Hood
  • 0.3-0.8m/s Inflow Air Velocity Small Fume Hood , CE Certificated Chemical Exhaust Hood

    Product Details:

    Place of Origin: CHINA
    Brand Name: MODULAR
    Certification: ISO14001, ISO 9001,CE,SGS
    Model Number: MBFH-C01

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 set or 1 unit
    Price: negotiable
    Packaging Details: safety package for transporation
    Delivery Time: within 7 - 20 workdays after recevided the deposit
    Payment Terms: L/C, D/A, D/P, T/T, Western Union
    Supply Ability: 10000 units per month
    Detailed Product Description
    Name: Benchtop Fume Hood Usage: Lab Exhuast Hood
    Size: 1500*800*2200mm Internal Size: 1280*600*1650mm
    Noise: ≤ 62dB Consumption: 400W

    What About Fume Hood Design Benchtop Fume Hood Lab Exhuast Hood

    Canopy hoods are horizontal enclosures having an open central duct suspended above a work bench or other area. Canopy hoods area most often used to exhuast areas that are too large to be enclosed within a fume hood.The major disadvantage with the canopy hood is that the contaminants are frawn directly past the user's breathing zone.

     

    Techenical Data:

    Model

    FH1500W

    external size

    1500*800*2200mm

    internal size

    1280*600*1650mm

    max opening

    1300mm

    exhuast airflow volume

    1500m³/h

    inflow air velocity

    0.3-0.8m/s

    noise

    62dB

    vibartion

    XYZ direct ≤ 4μm

     

    Fume hood design definitions

    Alarms, sensors, controls, and guages: Many of the newer VAV hoods are installed with alarms, sensors, controls and gauges.

    These features are incuded to provide lab personnel with a constant reading of fume hood performance. If the face velocity falls below an acceptable range the hood sensors will trigger an alarm to notify lab personnel.

    Low velocity alarms activate when the sash has been raised to a height at which the hood can no longer exhaust a sufficient amount of air, the building air exhaust system is not working properly, or there has been a power outage.

    When a low velocity alarm is activated, no hazardous chemical work should be performed until the exhaust volume is increased.

    Additionally, laboratory workers shold bot attempt to stop or disable hood alARMS. NU's Physical Plant should be notified for adjustment of air handling system exhaust and fume hood maintenance.

     

    0.3-0.8m/s Inflow Air Velocity Small Fume Hood , CE Certificated Chemical Exhaust Hood